Gas Analysis with the Mass Flowmeter : Quote, RFQ, Price and Buy

Jan 25, 2024

Need more information?

Let us help you with your inquiries, brochures and pricing requirements

The FMA-4100/4300 series mass flow totalizers and meters can be programmed remotely using the RS232 or RS485, functioning to measure the rate of gas flow and record it in 23 selectable units. These devices have a multitude of applications due to an extensive list of functions, including high and low gas flow alarms, gas flow totalizers, automatic zero adjustments, 2s relay outputs, jumper selectable 0 to 5 Vdc or 4 to 20 mA analogous outputs, status LED diagnostics, storable calibrations and internal or user-specific K-factors. The local LCD display has 2 lines, each of 16 characters and modifiable back lighting, which enables concurrent readings. Use of RS232 or RS485 enables access of further data, such as the temperature of CPU, auto zero, flow, linearization table adjustment, settings for both totalizer and alarms, gas table, conversion factors, selection of units and dynamic response compensation.

Both the local and remote activation of the FMA-4100 or 4300 enables automatic offset zero adjustment. This is particularly useful in situations where there is minimal flow through the meter when it is being modified. Digital commands enable the current automatic zero value to be read, saved or started. Totalizer settings can be altered in order to enable various functions: assigning action to a pre-set value, setting to zero, starting at a pre-set flow, starting/stopping totalizing and reading. Alarms can also be set up prior to use which can indicate both high and low flow, and can be appointed pre-set delay intervals of 0 to 3600 seconds, which activate the contact closer. An additional feature, called the latch mode control, functions to permits each relay to be latched on or ensure the interrelated alarm status. However, these transducers cannot be used to measure oxygen.

5-Point Traceable Calibration High Stable Wet/Dry Differential Pressure Transducers

Calibrate Your Temperature, Pressure and Other Process Control Devices at the Calibration Center

Calibrator for Thermocouple and RTDs

Constant Temperature Liquid Circulating Baths for Laboratory and Industrial Applications

Digital Pressure Gauge for Differential Pressures for High Accuracy

Displaying Temperature, Process, Rate and Time

High Accuracy Direct-to-Sensor for Real-Time Display

Infrared and Surface Calibrations with the Dry Block Temperature Calibrators

Measuring a Variety of DC Voltage and Current Outputs with the iS32 PID Controller

Measuring Clean Gases with Flowmeters

Measuring Conductive Liquids for Food and Wastewater Applications

Measuring Mass Flow Rate, Volume and Temperature with the FMC 5000 Coriolis Mass Flow Meter

Measuring Pressure and Temperature of Process Gases

Measuring Temperatures up to 200 °C with the Linear Strain Gauges

Monitoring Liquids and Energy with Ultrasonic Flowmeters

Portable Dry Block Calibrator for Field and Lab Work

Pressure Transducers for Industrial Applications

Reading Gas Mass Flow with the Gas Mass Flowmeters

The High Accuracy, Fast Sampling Platinum Digital Panel Meter Series for Temperature and Process Meters

SpecificationsCalibrations:Environmental (PER IEC 664):Flow Accuracy (Including Linearity):Repeatability:Flow Temperature Coefficient:Flow Pressure Coefficient:Turndown Ratio:Flow Response Time:Max Gas Pressure:Max Pressure Drop:Gas and Ambient Temperature:Relative Gas Humidity:Leak Integrity:Attitude Sensitivity:Output Signals:Relay:Transducer Input Power:Power Consumption:Wetted Materials:Standard Aluminum Models:Optional Stainless Steel Models:Optional O-ring Materials:Inlet and Outlet Connections:Model FMA-4100/4300:Optional:Display (FMA-4300 Models):Calibration Options:CE Compliance:Emission Standard:Class A Immunity Standard:EN 55082-1: